I will attach the lab manual and the results for this lab. I just need you to do the lab report that follows the rubric.The lab is called “Biochemical Oxygen Demand” Page 4-10 in the lab manual.If you have any questions ask me.
TABLE OF CONTENTS
Introduction ……………………………………………………………………………………………..1
Lab Safety……………………………………………………………………………………………….3
Biochemical Oxygen Demand…………………………………………………………………….4
Coliform Lab ………………………………………………………………………………………….11
Jar Test…………………………………………………………………………………………………16
Lake Profile……………………………………………………………………………………………20
Noise Pollution ……………………………………………………………………………………….27
Settleability of Solids……………………………………………………………………………….34
Solid Waste……………………………………………………………………………………………39
Solids ……………………………………………………………………………………………………43
ii
INTRODUCTION
Environmental Engineering is a profession directly involved
with the identification
and design solutions of environmental problems. Environmental
Engineers are
directly responsible for providing safe drinking water,
minimizing and preventing
pollution in rivers, lakes and oceans, treating and properly
disposing of municipal,
industrial and hazardous waste, and the remediation of
contaminated soil and
water, among other charges of the profession. Understanding
and mastering the
art of Environmental Engineering requires the integration of
biology, chemistry,
physics, mathematics, computer science, laboratory analyses,
and
communication skills.
The purpose of these experiments is to introduce you to
various aspects of
Environmental Engineering through laboratory analysis that
integrates hands-on
investigation, data reduction and interpretation. Experiments
include measuring
conventional water and wastewater parameters as well as
exploring the natural
environment. A more detailed description and professional
standards for a
majority of these experiments can be found in Standard
Methods for the
Examination of Water and Wastewater. Standard Methods, as
this book is often
referred to, is a joint publication of the American Public
Health Association, the
American Water Works Association and the Water Environment
Federation.
In each experiment, you will find material that relates to
both the theory and the
practical application of the laboratory in engineering
practice. The supplemental
web site for this manual is at:
http://civil.engr.siu.edu/nsflab/NSFProject/Environmental/Environ_Frame.htm
At this site additional learning tools such as video clips,
photographs, and sample
data sets are continually being added to illustrate key
concepts of the laboratory.
At this time, we are in the developmental stage of the site
and the lab manual.
We welcome and encourage the use of this material in your
courses. We only
request that you acknowledge us and let us know that you are
using it. Feedback
from you is both appreciated and invaluable to the
development of this project.
Please contact us if you have any comments, suggestions or
questions.
Lizette R. Chevalier, Associate Prof., Department of Civil
Engineering,
SIUC, [email protected]
James N. Craddock, Associate Prof., Department of Civil
Engineering,
SIUC, [email protected]
1
Partial support for this work is provided by the National
Science Foundation’s Course,
Curriculum and Laboratory Improvement Program under grant
DUE9952577. Additional
support is provided by Southern Illinois University
Carbondale College of Engineering,
College of Mass Communication and Media Arts and the
Materials Technology Center.
ENGINEERING
LAB SAFETY
A more thorough review of laboratory safety is presented
under General Topic
from the web site. The purpose of this laboratory is to
identify the location and
use of the following items in the laboratory. Review these
items with your lab
instructor prior to conducting any labs.
•
Safety glasses
•
Eye wash station
•
Shower
•
Latex gloves for BOD, Solids, Solid Waste and Coliform Labs
•
Insulated gloves and tongs for muffle furnace
•
Aprons
•
Spill kit
•
Fire extinguisher
•
Material Safety Data Sheet (MSDS)
•
Campus unit responsible for the pickup and disposal of waste;
Explain use
of request forms for pickup and the need for proper labeling.
In this lab, all chemicals must be in labeled containers. The
label on purchased
chemicals generally identifies the content adequately.
However, when you
prepare a reagent for use, it must be labeled as follows: The
name of the
chemical or reagent, the concentration, the date and your
name. You are
required to label every bottle used longer than one
laboratory period.
Figure 1: Example of proper labeling.
3
BIOCHEMICAL OXYGEN DEMAND
Introduction
In characterizing wastewater and surface water, the amount of
biodegradable
organics in the water is an important parameter. When these
organics degrade in
the aquatic environment, dissolved oxygen is consumed. Since
oxygen is not
very soluble in water (Table 1), a heavy loading of organics
may deplete oxygen
levels, which in turn may lead to fish kills and anaerobic
conditions. Although
most substances can also be degraded under anaerobic
conditions, the process
is slow and results in foul odors.
Biochemical oxygen demand, or BOD, is a test to measure the
consumption of
dissolved oxygen due to biological degradation of organic
materials and chemical
oxidation of inorganic materials. In fact, BOD is used as an
indicator to determine
compliance with wastewater discharge permits, in the design
of wastewater
facilities, to monitor plant performance, and to determine
the approximate
quantity of oxygen required to biologically stabilize or
oxidize organic matter.
BOD is also an important parameter in models that estimate
the assimilative
capacity of the receiving body of water.
The standard measurement is the BOD after five days (BOD5),
although BOD7 is
also used to correspond with work schedules, especially at
smaller plants. In this
procedure, dissolved oxygen is measured initially and after a
5 (or 7) day
incubation period. The BOD measured during this period is the
carbonaceous
BOD, since the bacteria that oxidize nitrogen are not in
sufficient numbers to
influence oxygen consumption until approximately seven days.
However, it is
common practice to use a nitrogen inhibitor. Seeding and
dilution of samples are
commonly used to ensure an acceptable change of dissolved
oxygen occurs.
Bacterial growth requires nutrients, including nitrogen,
phosphorus and trace
metals. These nutrients are added to dilution water, which is
also buffered to
ensure that the pH of the sample remains suitable for the
bacteria. Oxygen
consumed after 60-90 days of incubation is used to determine
the ultimate BOD.
Continuous oxygen uptake can be used to determine the
kinetics of degradation,
utilizing analysis tools such as the Thomas Method.
4
Table 1: Saturation of Dissolved Oxygen in Distilled Water
Temperature ºC
Solubility (mg/L)
Temperature ºC
Solubility (mg/L)
0
14.6
16
9.9
1
14.2
17
9.7
2
13.9
18
9.5
3
13.5
19
9.3
4
13.1
20
9.1
5
12.8
21
8.9
6
12.5
22
8.7
7
12.1
23
8.6
8
11.8
24
8.4
9
11.6
25
8.3
10
11.3
26
8.1
11
11.0
27
8.0
12
10.8
28
7.8
13
10.5
29
7.7
14
10.3
30
7.6
15
10.1
Application
The following figure shows a basic treatment train found at
municipal wastewater
treatment facilities. In this laboratory, you will be
measuring the BOD of the
influent and the effluent. One of the primary objectives of
municipal wastewater
treatment is the reduction of BOD in the effluent, which is
released into a
receiving body of water.
5
Figure 1: Generalized schematic of a wastewater treatment
facility.
Materials and Equipment
•
Standard BOD bottles with ground glass stoppers (300 mL).
•
Paraffin wrap.
•
Dissolved oxygen meter with appropriate DO probe.
•
Wide tipped volumetric pipet.
•
Magnetic stirrer if DO probe does not have a stirrer built
in.
•
Incubator: thermostatically controlled with a temperature of
20°C ± 1°C. All
light must be excluded form the samples during incubation.
•
Dilution water prepared by instructor.
•
Glucose-glutamic acid solution prepared by instructor.
•
Influent and effluent sample of wastewater from a local
municipal
wastewater treatment facility. Obtain the effluent sample
prior to
disinfection so that dechlorination and seeding will not be
required in this
laboratory.
Procedure
Samples should be used within 48 hours of collection. Samples
should be stored
at approximately 4°C to ensure that oxygen concentrations
remain constant. In
addition, samples should be incubated in the dark to prevent
oxygen
replenishment from photosynthesis. Prior to use, the sample
must be brought to
room temperature. The pH of samples must be between 6.5 and
7.5 to ensure
biological growth. The pH of samples can be adjusted with a
solution of sulfuric
acid (H2SO4) or sodium hydroxide (NaOH). To increase the pH
of a sample, you
need to add a base. In Standard Methods, the pH of a BOD
sample is increased
by adding sodium hydroxide (NaOH). Dissolve 40 g sodium
hydroxide in distilled
water. Dilute to 1 L.
6
Since the actual BOD5 is not known, several dilutions must be
prepared and
tested. Typical municipal influent wastewater has a BOD5 of
150-350 mg/L,
whereas the effluent ranges between 10-40 mg/L. For this
laboratory, prepare
three dilutions of each sample. Use Table 2 to determine the
required dilutions.
Prepare one dilution in the appropriate range, then one below
and above.
Using the effluent sample, prepare two BOD bottles at each of
the three dilutions.
To prepare the dilution, place the required amount of sample
in the bottle.
Completely fill the remainder of the bottle with dilution
water, taking care not to
entrap air bubbles. Place the glass stopper on the bottle,
allowing for a small
amount of water to spill off the bottle. There should be a
water seal remaining in
the lip area. This water seal will prevent oxygen from
entering the bottle. As an
additional precaution, wrap a piece of paraffin wrap over the
top of the bottle.
Repeat this procedure for the influent sample. Use one set of
each dilution to
measure the initial DO, and incubate the other set. Place the
remaining six
bottles (three influent and three effluent dilutions) in the
incubator. Record the
time and date. As with the samples collected from the
treatment facility, these
prepared samples must be kept in the dark to prevent oxygen
replenishment
from photosynthesis and at a constant temperature of 4°C to
ensure that oxygen
concentrations remain constant.
Table 2: Dilution ranges for pipetting into 300 mL BOD
bottles.
Sample Volume
(mL)
Minimum BOD
(mg/L)
Maximum BOD
(mg/L)
1
600
2400
3
200
800
5
120
480
10
60
240
30
20
80
50
12
48
100
6
24
200
3
12
300
2
8
After the required incubation period (5 or 7 days), remove
the BOD bottles from
the incubator and measure the final dissolved oxygen levels.
7
Check the dilution water blank to be certain that the DO
uptake (DOinitial – DOfinal)
was not more than 0.2 mg/L. If the value is above 0.2 mg/L,
the results are
suspect. A valid dilution is one that has a final DO greater
than or equal to 1
mg/L and a DO uptake of at least 2 mg/L.
Place 6 ml of the glucose-glutamic acid standard in two BOD
bottles. Then add
15 mL of wastewater effluent for seed. Fill the remainder of
the bottle with dilution
water. Use one bottle to determine the initial DO. Incubate
the second bottle with
the other samples and measure the final BOD after 5 days.
Also prepare two blank samples of dilution water. Use one
bottle to determine the
initial DO. Incubate the second bottle with the other samples
and measure the
final BOD after 5 (or 7) days.
Make sure to properly label all bottles. The label should
state what is in the
bottle, the concentration, the date, and your name.
Analysis
As stated earlier, a valid dilution is one that has a final
DO of at least 1 mg/L, and
a DO uptake of at least 2 mg/L. The BOD of the sample is
determined from the
DO uptake and the fractional dilution (F):
BOD =
DOinitial − DO final
F
The fractional dilution of the sample is the volume of sample
divided by the BOD
bottle volume.
Because the BOD test is a bioassay, the results can be
influenced greatly by the
presence of toxic substances. Distilled waters, which is used
to prepare the
dilution water, are frequently contaminated with copper. Use
the bottles with the
glucose-glutamic acid to check for water quality as well as
seed effectiveness
and the quality of your analytical technique. The BOD5 for
this 300 mg/L mixed
primary standard should be 198 ± 30.5 mg/L if a nitrogen
inhibitor was used.
Elements of Report
Within your report, you should include the following items
specific to your
experiment:
•
Name, location and general description of wastewater facility
•
Specific equipment (manufacturer and model) used and accuracy
•
Which dilution provided the best estimate of BOD5 for the
influent and the
effluent?
•
Identify any BOD samples that should be eliminated based on
the final DO
or the minimum DO depletion.
8
•
What is BOD5 of the influent and effluent, and how does this
value
compare to typical values reported in the literature?
•
What are the different compounds added to the dilution water?
What
purpose does each serve?
•
If you conducted a 7 day BOD test, calculate BOD5 and the
ultimate BOD
(Lo) of the sample assuming k=0.35/day (base e). Generate a
graph
showing the change in BOD over time. Extend this graph to at
least 0.9Lo.
•
If you conducted a 5 day BOD test, calculate BOD7 and the
ultimate BOD
(Lo)of the sample assuming k=0.35/day (base e). Generate a
graph
showing the change in BOD over time. Extend this graph to at
least 0.9Lo.
References
Standard Methods for the Examination of Water and Wastewater,
20th Ed.
Published jointly by APHA, AWWA and WPCF, 1998.
Laboratory Manual for CE 310: Introduction to Environmental
Engineering,
Spring 2000, Ray, B.T., Southern Illinois University
Carbondale.
Wastewater Engineering: Treatment, Disposal and Reuse, 3rd
Ed., Metcalf and
Eddy, McGraw-Hill, 1991.
Standard Handbook of Environmental Engineering, Corbitt,
R.A., McGraw-Hill,
1990.
9
Biochemical Oxygen Demand Lab Data Sheet
Name _________________________
Date _________________________
Laboratory Section _________________________
Treatment Facility _________________________
Initial Date and Time _________________________
Final Date and Time _________________________
Volume
WW
mL
Sample
DO
Initial DO Final DO uptake
mg/L
mg/L
mg/L
1
2
3
4
5
6
Dilution
Blank
Water
G-GA Standard
EQUIPMENT USED (include model numbers):
NOTES:
10
F
BOD
mg/L
COLIFORM LAB
Introduction
Pathogenic organisms present in water and wastewater are
difficult to test for,
and are often in small numbers. Therefore, the typical
approach is to test for the
presence of indicator organisms such as the coliform group.
The coliform
bacteria are present in the intestinal tract of mammals.
Although not pathogenic
themselves, the presence of coliform bacteria in large
numbers may indicate the
possibility of contamination of the water supply by fecal
matter or insufficient
treatment of a wastewater. One analytical method commonly
used by regulatory
agencies and water utilities to test for coliform is the
membrane filter technique.
The objective of this laboratory is to conduct this
experiment, using different
sources of water and wastewater.
Materials and Equipment
•
Vacuum System
•
0.45 m membrane filter
•
Filtration apparatus
•
Pipets
•
Graduated cylinder
•
Petri dishes (pre-sterilized plastic dishes are available
commercially)
•
Absorbent pads
•
Tweezers
•
Incubator (35±0.5°C with a relative humidity of at least 60%)
•
M-Endo medium (prepared by lab instructor)
•
Sterilized buffered dilution water (prepared by lab
instructor)
•
Water and/or wastewater sample collected in sterilized glass
or plastic
bottles
11
Note: Anything contacting the sample must be sterilized to
prevent
contamination. This includes, but is not limited to,
glassware, filters, pipets and
the filtration apparatus.
Procedure
Collect two different water samples from different sources.
If collecting from a
treatment facility, collect the sample prior to chlorination
if possible. Otherwise,
the chlorine must be neutralized with sodium thiosulfate
immediately after
collecting. Drinking water samples should also be
dechlorinated. Some
manufacturers of sample bottles place sodium thiosulfate in
the sample bottles
prior to distribution.
Using sterile forceps, place a sterile membrane filter (grid
side up) over the
porous plate of the flask of the filter device. Place the
funnel unit over the flask
and lock it in place. Shake your sample 25 times to assure
that it is well mixed.
Pipet the required volume of sample into the top of the
filter apparatus. For
drinking water, 100 mL is the standard sample size. Filter
the sample under a
partial vacuum. A satisfactory filtration time is within five
minutes. If this cannot
be obtained, the required volume may be distributed among
numerous
membranes (i.e. 100 mL may be filtered in two 50 mL or four
25 mL portions).
For analyzing samples other than drinking water, the required
volume may be
estimated using Table 1. Because the range of sample volume
is large, it is best
to analyze other waters by filtering three different sample
volumes. When less
than 10 mL of sample is to be filtered, add approximately 10
mL of sterile dilution
water to the funnel before filtration. Alternately, you may
pipet the sample into a
sterile bottle and mix with approximately 10 mL of sterile
dilution water first, and
then filter the entire amount. This increase in water volume
aids in the uniform
dispersion of the bacteria over the effective filtering
surface.
Table 1: Approximate filtration volume
Source
Drinking water
Lakes
Bathing beaches
Streams, rivers
Unchlorinated wastewater
Approximate Volume
100
10-100 mL
0.01-10 mL
0.01-10 mL
0.0001-0.1 mL
After filtering the sample, and with the filter still in
place, rinse the interior surface
of the funnel with 20 to 30 mL of sterile dilution water
three times (this may be
applied from a squeeze bottle).
Place an adsorbent pad in the bottom of a sterilized petri
dish. Saturate the pad
with 1.8-2.2 mL of M-Endo medium. Decant any excess medium.
Remove the
filter from the filtration device using sterile forceps.
Place in on the saturated pad
12
using a rolling motion to avoid the entrapment of air. The
contact with the
medium is important, since the colonies will not grow without
this contact.
Place the prepared cultures in waterproof bags and incubate
in a submerged
water bath for 22-24 hr at 35±0.5°C. Do not incubate beyond
24 hr. After
incubating, remove the cultures. Count any colonies that
develop a red color with
a metallic sheen. These are colonies of coliform bacteria.
Report the results as #
of colonies/100 mL. Other bacteria may be present, but will
not exhibit the
characteristic color and sheen. These colonies may be pink,
blue, or white
lacking sheen.
In addition to the samples, test the dilution water. Evidence
of contamination in
this sample indicates unsterile conditions and invalid data.
A number of improper
procedures can result in less than desirable cultures.
Analysis
A suitable quantity of the sample water results in an ideal
colony count of 20 to
80 coliform colonies and not more than 200 colonies. Less …